Tip for printing with a MetroLux II

I was printing yesterday and noticed all my times seemed funny. Turned out, I was printing with Lux 2 and I usually use Lux 1. On my unit, those have different calibration numbers, but they don't need to because I only use one light source. I'm going to change the Lux 1 and Lux 2 calibration numbers to be the same so that it doesn't matter.

Pocket Spot

Pocket Spot
Metering in the Office, 10 2/3 EVs

Pocket Spot

Pocket Spot
Metering in the Office, 4 1/3 EVs

Pocket Spot Spec Sheet

Pocket Spot Digital Light Meter Specs

Display: 2-digit Red LED with 1/3, 2/3 LED indicators

Dial: White, laser-engraved on Meter's anodized color background. Intermost dial is ISO with f/# on the outside. f/1.0 to f/128. Outer dial is shutter speeds from 8 minutes to 1/4000 sec on the inside and EV on the outside. EVs from -1 to 20. Body is marked with Zones from Zero to X (10). [Romans didn't have a zero, but what are you going to do? ]

ISO: 3 to 12800 ISO, marked in 1/3 stops

EV range: -1 2/3 to 23 at 100 ISO

Spectral Sensitivity: Compensated for "typical" B&W film, i.e. HP5+ or Tri-X

Angle of View: approximately 1 degree, smaller at very high EVs and 3 degrees at lower EVs

Viewing: Bore-sight through the hole the length of the chassis. Meter is held about 12" or 300mm from the eye (length of strap)

Linearity: about 1% from low to high.

Calibration: Not required. No adjustments inside.

Finish: Black anodized over a solid block of machined aluminum. Texture is random tumble over stones before anodize. Other colors in consideration at extra cost are RED and BLUE.

Battery: 6V PX28 or equivalent, Supplied

Dimensions: 2.25" x 2" x 3/4" (L x W x T) 57 x 50 x 19 mm
Dial on top is 1/8" thick, 3 mm

Weight: 4 1/8 oz (117 grams) with strap and battery, both included.


specifications subject to change

More pictures on page two near bottom.